TenderAxiom

TenderAxiom · Opportunities

Purchase Olsun Electrics 225 KVA Transformer: requirements and submission rules

30 requirements and 5 submission rules found in the solicitation documents for 47QSSC27Q0028. Use them as the start of your compliance matrix.

Solicitation number
47QSSC27Q0028
Agency
GENERAL SERVICES ADMINISTRATION / FEDERAL ACQUISITION SERVICE / GSA/FAS/GSS/QSCB, SUPPLY CHAIN MANAGEMENT CONTRACTING DIVISION
NAICS
334416
Set-aside
No Set aside used
Responses due
07 December 2026 (9 days)
Official notice
View on SAM.gov

Submission rules that can disqualify a bid

  • As a minimum, offers shall include— (1) The solicitation number; (2) The name, address, telephone number of the Offeror; (3) The Offeror’s Unique Entity Identifier (UEI) and, if applicable, Electronic Funds Transfer (EFT) indicator; (4) Information necessary to evaluate the factors contained in the provision at 52.212-2 or as described in the solicitation;
  • (c) Late submissions, modifications, revisions, and withdrawals of offers.
  • Submit signed and dated offers to the office specified in this solicitation at or before the exact time specified in this solicitation.
  • All quotes must be submitted via email upon the close date of the RFQ to be considered for award.
  • Quoter must be registered in the System for Award Management (SAM) database before an award can be made to them.

Requirements

IDRequirement
R1PLEASE COMPLETE THE FOLLOWING INFORMATION: 1. OFFEROR: Company Name, Address, Name of Company Rep, Title, Phone, Fax, Email, UEI Number, Is your company a dealer or manufacturer?, Business Size
R2Please provide pricing for the following NSN. See Terms & Conditions on following pages. Olsun Electrics 225 KVA Transformer (Qty 1), Testing-Post Shipping (Qty 1), Shipping (Qty 1), Total
R3Delivery shall be FOB Destination, CONUS (IAW FAR 47.303-6). Yes ______ No ______.
R4The below requirements marked with an (x) are to be completed and/or acknowledged. If any applicable blanks are not complete, the vendor’s quote will NOT be considered for award.
R5Will comply with all terms and conditions of the solicitation. Yes ______
R6Is registered with OMS Vendor Portal or EDI to receive orders electronically. Yes ______ No_______
R7If not registered at time of quote submission, vendor will be required to be registered prior to award. Only the lowest quoting offeror will be assisted with registration if not previously registered.
R8Provided all requested documents by the close date and time of the solicitation to include: Pages 1 and 2 of this document: Yes ______
R9All required Provision and Clause fill-ins submitted (as applicable)
R10My company is registered with SAM.gov and has provided responses to the provisions that require Offeror completion of information, representations, and certifications: Yes ______ No_______.
R11In accordance with Provision 52.240-90(c) (GSA Class Deviation RFO-2025-12), Covered telecommunications equipment or services representations. By submission of its offer, the Offeror represents that, after conducting a reasonable inquiry (1) It will not provide covered telecommunications equipment or services to the Government in the performance of any contract, subcontract or other contractual instrument resulting from this solicitation, except as waived by the solicitation, or as disclosed in paragraph (g); and (2) It does not use covered telecommunications equipment or services, or use any equipment, system, or service that uses covered telecommunications equipment or services, except as waived by the solicitation, or as disclosed in paragraph (g). Yes ______ No_______.
R12Offeror certifies that they will comply with all requirements in Provision 52.240-91 (GSA Class Deviation RFO-2025-12) Security Prohibitions and Exclusions. Yes ______ No_______.
R13Quoted on the brand name item as specified in the attached requirements: Yes ______.
R14Read, sign, and returned attached MIL-STD-129R Compliance Form IAW Clause 552.211-73: Yes ______ OR if your company has a completed form on file for the Instaquote program check here: Yes ______. Only one yes should be selected.
R15SELF CERTIFICATION: By signing below, you are certifying that the information submitted on this form is accurate and meets the requirements listed in the RFQ. In the event your firm ships an item that does not meet the specifications of the requirement, your firm will be responsible for a refund of the payment, or a correct replacement item and any cost incurred by the government. Signature: Date:
R16Any vendor submitting a quote, must be a registered user and able to accept POs in GSA’s Order Management Services (OMS) Vendor Portal or have the ability to receive orders via Electronic Data Interchange (EDI) prior to award.
R17The Offeror agrees to hold the prices in its offer firm for 60 calendar days from the date specified for receipt of offers, unless another time period is specified in an addendum to the solicitation.
R18Purchase is designated as brand name as supported by a Justification for Other Than Full and Open Competition, and no substitutions will be accepted.
R19The Contractor will not engage in any racially discriminatory DEI activities
R20The Contractor must include the substance of this clause, including this paragraph (c), in subcontracts at any tier, including those for commercial products and commercial services, except those where the place of delivery or performance is outside the United States.
R21Olsun Electrics 225kVA Cast Coil Transformer, Copper Wound, Padmount, Dry Type, 316 SS, Munsell Green Paint, 12kV-208Y/120, Delta-Wye (Step-Down) for customer unit: Pad B4-PS4-T62
R22PAD MOUNTED, NEMA 3R, COLD ROLLED STEEL, ENCLOSURE FOR OUTDOOR USE
R23TAMPER RESISTANT, COMPARTMENTALIZED DESIGN WITH PADLOCKABLE DOOR
R24DEAD FRONT, RADIAL FEED
R253 - 200 AMP BUSHING WELLS
R26TRANSFORMER SPECIFICATIONS: Cast Coil Transformer 225 KVA, 3 Phase, 60 Hertz, K Factor: 1, Design Impedance: 5.75% Minimum, Temp. Rise: 80C, Max. Ambient Temp: 40C, 180 Deg. C Insulation, AA Air Cooled
R27VOLTAGES: Pri. Volt: 12000D, Sec. Volt: 208Y/120, Pri. BIL: 95, Sec. BIL: 30, Pri. Taps: +/-2 (2.5%) None, Conductor: Copper Wound Conductor: Copper Wound
R28ENCLOSURE: Enclosure: Padmount, NEMA: 3R Paint: Munsell Green 7GY3.29.1.5, Material/Finish: 316 Stainless Mount: Floor
R29VECTOR CONFIGURATIONS: DELTA- Wye (STEP DOWN) (Dyn1) Other
R30Certified Testing Post Shipping Includes IEEE/ANSI Standard production tests.

Recent awards in NAICS 334416

The newest federal contract awards in the same industry code from General Services Administration, since 1 October 2024. Use them to see who wins this kind of work and at what value.

StartAwardee and buyerAward value
2025-04-04RESION LLCFederal Acquisition Service · DO 4 CCA ELECTRONIC REPLACEMENT COMPONENTS$179,839
2025-02-10RESION LLCFederal Acquisition Service · DO 3 CCA ELECTRONIC REPLACEMENT COMPONENTS$230,733

Source: USAspending.gov, retrieved 2026-10-29. Award value is the obligated amount reported by the agency.

Automated reading of the documents attached to the notice on SAM.gov when it was posted. Amendments may change them. The official notice always takes precedence.

Bidding on this? Before you submit, check that every claim in your draft is backed by your records and every requirement above is answered.

Bidding? Get a reminder 5 days before it is due

One email, with what to check before you submit. Nothing else.

Amendment issued? Compare it with the original to see every changed requirement, date and limit, free.

Get new solicitations that match your business, free

Enter NAICS codes, keywords or both. No email when nothing matches. Unsubscribe in one click.