Request for Lease Proposal - Kenai Outstation - Soldotna, Alaska: requirements and submission rules

65 requirements and 15 submission rules found in the solicitation documents for 36C24W270006. Use them as the start of your compliance matrix.

Solicitation number
36C24W270006
Agency
VETERANS AFFAIRS, DEPARTMENT OF / VETERANS AFFAIRS, DEPARTMENT OF / 260-NETWORK CONTRACT OFFICE 20 (36C260)
NAICS
531120
Set-aside
No Set aside used
Responses due
26 November 2026 (closed)
Official notice
View on SAM.gov

Submission rules that can disqualify a bid

  • This information must be submitted NO LATER THAN the submission of the DIDs, if applicable.
  • 36C24W26L0023, PAGE 11 LESSOR: ________ GOVERNMENT: ________ GSA TEMPLATE L100 REV (2/26) under Section 12 of the Contract Disputes Act of 1978, as amended (41 USC § 611), that is in effect on the day after the due date.
  • The Energy Independence and Security Act (EISA) establishes the following requirements for Government Leases in Buildings that have not earned the ENERGY STAR® Label conferred by the Environmental Protection Agency (EPA) within one year prior to the due date for final proposal revisions (“most recent year”).
  • The Lessor must submit to GSA, as part of the shell cost, complete DIDs conforming to the requirements of this Lease and other Government -supplied information related to the tenant agency's interior build- out requirements not later than XX Working Days following the Lease Award Date, provided that the Government supplies such information and direction as reasonably required for Lessor to timely complete DIDs.
  • Each TI proposal must be (1) submitted by the proposed general contractors (or subcontractors) using the TICS Table in CSI Masterformat (filling out all sheets, including each division tab, as necessary and (2) reviewed by the Lessor prior to submission to the Government to ensure compliance with the scope of work (specified above) and the proper allocation of shell and TI costs.
  • Recipient contractors must be registered as “active” in the System for Award Management (SAM) database at www.sam.gov, and have a Lawful Government Purpose to access such information.
  • If a subcontractor is not registered in the SAM database and has a Lawful Government Purpose to possess CUI building information in furtherance of the contract, the subcontractor must provide to the contractor its DUNS number or its tax ID number and a copy of its business license.
  • Submit the results and supporting data (sample location, device type, duration, radon measurements, laboratory proficiency certification number, and the signature of a responsible laboratory official) within 30 days after the measurement.
  • As a condition for being recognized as the Lessor and entitlement to receiving rent, the Transferee must register in the System for Award Management (SAM) for purposes of “All Awards” (See FAR 52.232-33), and complete all required representations and certifications within SAM.
  • The Lessor must submit a written commissioning plan prior to completion of CDs.
  • After start of construction, the Lessor must submit to the Government written progress reports at intervals of XX Working Days.
  • 36C24W26L0023, PAGE 26 LESSOR: ________ GOVERNMENT: ________ GSA TEMPLATE L100 REV (2/26) 4.03 LEASE SUBMITTALS (FEB 2026) The Lessor must submit to the LCO or designated representative or the Government’s project management system: A.
  • All required finish option samples must be provided at no additional cost to the Government within 10 Working Days after initial submission of DIDs, if applicable.
  • Submit a copy of the manufacturer’s standard warranty to the LCO within the first 60 days of Government occupancy.
  • Thermostats must be secured from manual operation by key or locked cage.

Requirements

IDRequirement
R1Do not attempt to complete this lease (GSA Lease Template L100, hereinafter Lease Template). Upon selection for award, GSA will transcribe the successful Offeror's final offered rent and other price data included on Offeror’s submitted GSA Lease Proposal Form 1364, (hereinafter Lease Proposal Form) into a Lease Template, and transmit the completed Lease Template, together with appropriate attachments, to the successful Offeror for execution.
R2The Building in which the Premises are located must be designed, built and maintained in good condition and in accordance with the lease requirements. If not new or recent construction, the Building must have undergone by occupancy, modernization, or adaptive reuse for office space with modern conveniences. The Building must be compatible with its surroundings. Overall, the Building must project a professional and aesthetically pleasing appearance including an attractive front and entrance way.
R3In addition, the Lessor must provide such additional parking spaces as required by the applicable code of the local government entity having jurisdiction over the Property.
R4Lessor must provide to the Government, in exchange for the payment of rental and other specified consideration, the following: 1. The leasehold interest in the Property described herein in the paragraph entitled “The Premises and Building.” 2. All costs, expenses and fees to perform the work required for acceptance of the Premises in accordance with this Lease, including all costs for labor, materials, and equipment, professional fees, subcontractor fees, attorney fees, permit fees, inspection fees, and similar such fees, and all related expenses. Performance or satisfaction of all other obligations set forth in this Lease; and all services, utilities, and maintenance required for the proper operation of the Property, the Building, and the Premises in accordance with the terms of the Lease, including, but not limited to, all inspections, modifications, repairs, replacements, and improvements required to be made thereto to meet the requirements of this Lease.
R5All relevant tax adjustment documentation (e.g., copies of paid tax receipts, invoices) must be submitted online at leasing.gsa.gov or a successor portal.
R6Before the Government accepts the Space, the Lessor must complete the following additional Building improvements, as part of shell rent: A. _______________ B. _______________ C. _______________
R7Signatories to this Lease must have full authority to bind their respective principals with regard to all matters relating to this Lease.
R8If title is transferred, the Lessor must notify the Government within five days of the transfer of title.
R9In order to obtain a tax adjustment, the Lessor must furnish the LCO with copies of all paid tax receipts, or other similar evidence of payment acceptable to the LCO, and a proper invoice (as described in GSA 3517, General Clauses, 552.270- 31, Prompt Payment) for the requested tax adjustment, including the calculation thereof. All such documents must be received by the LCO within 60 calendar days after the last date the real estate tax payment is due from the Lessor to the Taxing Authority without payment of penalty or interest. FAILURE TO SUBMIT THE PROPER INVOICE AND EVIDENCE OF PAYMENT WITHIN SUCH TIME FRAME MUST CONSTITUTE A WAIVER OF THE LESSOR’S RIGHT TO RECEIVE A TAX ADJUSTMENT PURSUANT TO THIS PARAGRAPH FOR THE TAX YEAR AFFECTED.
R10Within ten (10) calendar days after the LCO issues the Notice To Proceed (NTP) for TI construction, the Lessor must provide to the LCO evidence of: 1. Award of a construction contract for TIs with a firm completion date. This date must be in accordance with the construction schedule for TIs as described in the “Schedule for Completion of Space” paragraph of this Lease. 2. Issuance of required permits for construction of the TIs.
R11Lessor may not use Federal agency name(s) and/or acronym(s), e.g., General Services Administration, GSA, in its entity name that owns and/or leases Space to GSA.
R12All work in performance of this Lease must be done by skilled workers or mechanics and must be acceptable to the LCO.
R13The Lessor must reuse items or materials in the construction phase of the project, as long as such meet the quality standards set forth by the Government in this Lease.
R14Particle board, medium-density fiberboard, and hardwood plywood must be free of formaldehyde and labeled as Toxic Substances Control Act (TSCA) Title VI compliant. Other wood types such as strawboard must be free of formaldehyde or sufficiently aged prior to use such that indoor air levels in the finished leased space must not exceed 0.016 parts per million (ppm) of formaldehyde.
R15All materials comprised of combustible substances, such as wood plywood and wood boards, must be treated with fire retardant chemicals by a pressure impregnation process or other methods that treats the materials throughout as opposed to surface treatment.
R16All adhesives employed (including, but not limited to, adhesives for carpet, carpet tile, plastic laminate, wall coverings, adhesives for wood, or sealants) must meet the requirements of the manufacturer of the products adhered or involved. The Lessor must use adhesives and sealants with no heavy metals, and that do not result in indoor air levels above 0.016 parts per million (ppm) of formaldehyde. Adhesives and other materials used for the installation of carpets must be limited to those having a flash point of 140 degrees F or higher.
R17The Building Shell must be designed, constructed, and maintained in accordance with the standards set forth herein and completed prior to acceptance of Space.
R18The Lessor must be responsible for the professional quality, technical accuracy, and the coordination of all designs, drawings, specifications, and other services furnished by the Lessor under this contract. The Lessor must, without additional compensation, correct or revise any errors or deficiencies in its designs, drawings, specifications, or other services.
R19Vestibules must be provided at public entrances wherever entry to the Space is directly from the outside. In the event of negative air pressure conditions, provisions must be made for equalizing air pressure.
R20The Lessor must provide permanent entryway systems (such as grilles or grates) to control dirt and particulates from entering the Building at all primary exterior entryways.
R21Prior to occupancy, the Premises and any parking garage areas must meet or will be upgraded to meet, either the applicable egress requirements in the National Fire Protection Association, Life Safety Code (NFPA 101), or the International Code Council, International Building Code (IBC), each current as of the Lease Award Date, or use an alternative approach or method that achieves an equivalent level of safety deemed acceptable by the Government.
R22The Space must have unrestricted access to a minimum of two remote exits on each floor of Government occupancy.
R23Any portion of the Space located below- grade, including parking garage areas, and all areas in a Building referred to as "hazardous areas" (defined in National Fire Protection Association (NFPA) 101) that are located within the entire Building (including non- Government areas) must be protected by an automatic fire sprinkler system or an equivalent level of safety.
R24Automatic fire sprinkler system(s) must be installed in accordance with the requirements of NFPA 13, Standard for the Installation of Sprinkler Systems that was in effect on the actual date of installation.
R25Automatic fire sprinkler system(s) must be maintained in accordance with the requirements of NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-based Fire Protection Systems (current as of the Lease Award Date).
R26A Building-wide fire alarm system must be installed in the entire Building in which any portion of the Space is located on the 3rd floor or higher.
R27The fire alarm system must be installed in accordance with the requirements of NFPA 72, National Fire Alarm and Signaling Code, that was in effect on the actual date of installation, and maintained in accordance with the requirements of NFPA 72 (current as of the Lease Award Date).
R28If the Building’s fire alarm control unit is over 25 years old as of the date of award of this Lease, Lessor must install a new fire alarm system in accordance with the requirements of NFPA 72, National Fire Alarm and Signaling Code (current as of the Lease Award Date), prior to Government acceptance and occupancy of the Space.
R29The Lessor must provide suitable passenger elevator and, when required by the Government, freight elevator service to any of the Premises not having ground level access. Service must be available during the normal hours of operation specified in the in this Lease.
R30The Lessor must remove existing abandoned electric, telephone, and data cabling and devices, as well as any other improvements or fixtures in place to accommodate the Government’s requirements. Any demolition of existing improvements that is necessary to satisfy the Government’s layout must be done at the Lessor’s expense.
R31The Building, leased Space, and areas serving the leased Space must be accessible to persons with disabilities in accordance with the Architectural Barriers Act Accessibility Standard (ABAAS), Appendices C and D to 36 CFR Part 1191 (ABA Chapters 1 and 2, and Chapters 3 through 10) and 36 CFR 1190 to the extent applicable. To the extent the standards referenced in the preceding sentence conflicts with local accessibility requirements, the more stringent must apply.
R32A complete acoustical ceiling system (which includes grid and lay-in tiles or other Building standard ceiling system as approved by the LCO) throughout the Space and Premises must be required. The acoustical ceiling system must be furnished, installed, and coordinated with TIs. Ceilings must be at a minimum 9 feet and 0 inches and no more than 12 feet and 0 inches measured from floor to the lowest obstruction.
R33Office Space must have windows in each exterior bay unless waived by the LCO. All exterior window assemblies must be locked, weather resistant and watertight.
R34Permanent partitions must extend from the structural floor slab to the structural ceiling slab. They must be provided by the Lessor as part of shell rent as necessary to surround the Space, stairs, corridors, elevator shafts, restrooms, all columns, and janitor closets. They must have a flame spread rating of 25 or less and a smoke development rating of 450 or less (ASTM E-84).
R35No insulation installed with this project must be material manufactured using chlorofluorocarbons (CFCs), nor must CFCs be used in the installation of the product. All insulation must contain low emitting volatiles and not result in indoor air levels above 0.016 parts per million (ppm) of formaldehyde.
R36All adjoining floor areas must be of a common level not varying more than 1/4 inch over a 10-foot horizontal run in accordance with the American Concrete Institute standards, non-slip, and acceptable to the LCO. Office areas must have a minimum live load capacity of 50 pounds per ABOA SF plus 20 pounds per ABOA SF for moveable partitions. Storage areas must have a minimum live load capacity of 100 pounds per ABOA SF, including moveable partitions.
R37The Lessor must provide and operate all Building equipment and systems in accordance with applicable technical publications, manuals, and standard procedures. Mains, lines, and meters for utilities must be provided by the Lessor. Exposed ducts, piping, and conduits are not permitted in office Space.
R38Whenever requested, the Lessor must furnish to GSA as part of shell rent, a report by a registered professional engineer(s) showing that the Building and its systems as designed and constructed will satisfy the requirements of this Lease.
R39Main service facilities must be enclosed. The enclosure may not be used for storage or other purposes and must have door(s) fitted with an automatic deadlocking latch bolt with a minimum throw of 1/2 inch. Main distribution system... for standard office occupancy must be provided at the Lessor’s expense... In no event must such power distribution (not including lighting and HVAC) for the Space fall below 4 watts per ABOA SF.
R40On each floor of Government-occupied Space, the Lessor must provide drinking fountain(s) with chilled potable water within 200 feet of travel from any Government-occupied area on the floor. The fountains must comply with Section F211 of the Architectural Barriers Act Accessibility Standard.
R41If no new construction of a restroom is occurring, at a minimum, separate restroom facilities for men and women must be provided with sufficient fixtures (water closets, sinks and urinals), in accordance with local code or ordinances. Each restroom must have water closets enclosed with stall partitions and doors, urinals (in men's room), and hot... and cold water... These facilities must be located on each floor occupied by the Government in the Building and must be located so that employees will not be required to travel more than 500 feet on one floor to reach the restrooms.
R42Central HVAC systems must be installed and operational, including, as appropriate, main and branch lines, VAV boxes, dampers, flex ducts, and diffusers, for an open office layout, including all Building common areas. The Lessor must provide conditioned air through medium pressure duct work at a rate of .75 cubic feet per minute per ABOA SF and systems must be designed with sufficient systems capacity to meet all requirements in this Lease.
R43Temperature control for office Spaces must be provided by concealed central heating and air conditioning equipment. The equipment must maintain Space temperature control over a range of internal load fluctuations of plus 0.5 W/SF to minus 1.5 W/SF from initial design requirements of the tenant.
R44Sufficient space must be provided on the floor(s) where the Government occupies Space for the purposes of terminating telecommunications service into the Building. The Building’s telecommunications closets located on all floors must be vertically stacked. Telecommunications switch rooms, wire closets, and related spaces must be enclosed. The enclosure must not be used for storage or other purposes and must have door(s) fitted with an automatic door-closer and deadlocking latch bolt with a minimum throw of 1/2 inch.
R45The Lessor must allow the Government’s designated telecommunications providers access to utilize existing Building wiring to connect its services to the Government’s Space. If the existing Building wiring is insufficient to handle the transmission requirements of the Government’s designated telecommunications providers, the Lessor must provide access from the point of entry into the Building to the Government’s floor Space, subject to any inherent limitations in the pathway involved.
R46High efficiency T-8, T-5, or LED light fixtures (and associated ballasts or drivers) must be installed to match the other luminaries in the Space as either ceiling grid or pendant mounted for an open -office plan. Newly installed lighting must use LED fixtures with replaceable dimmable drivers. The dimmable drivers must use 0- 10V or digital control signals and must be compatible with any existing control systems. Ceiling grid fixtures must be either 2’ wide by 4’ long or 2’ wide by 2’ long. Lessor must provide, as part of Shell Rent, a minimum overall lighting fixture efficiency of 85 percent.
R47Fixtures must have a minimum of two tubes and must provide 50 foot-candles at desktop level (30” above finished floor) with a maximum uniformity ratio of 1.5:1. Lessor must provide, as part of Shell Rent, 10 average foot- candles in all other Building areas within the Premises with a uniformity ratio of 4:1. Emergency egress lighting levels must be provided in accordance with the local applicable building codes (but not less than 1 foot-candle, measured at the floor) by either an onsite emergency generator or fixture mounted battery packs.
R48The Lessor must provide ceiling or wall mounted occupancy sensors, or vacancy sensors (preferred), or scheduling controls through the building automation system (BAS) throughout the Space in order to reduce the hours that the lights are on when a particular space is unoccupied. No more than 1,000 square feet must be controlled by any one sensor.
R49Exterior egress, walkway, parking lot, and parking structure lighting must have emergency power backup to provide for safe evacuation of the Building.
R50Where demolition or construction work occurs adjacent to occupied Space, the Lessor must erect appropriate barriers (noise, dust, odor, etc.) and take necessary steps to minimize interference with the occupants. This includes maintaining acceptable temperature, humidity, and ventilation in the occupied areas during window removal, window replacement, or similar types of work.
R51The Lessor must incorporate commissioning requirements to verify that the installation and performance of energy consuming systems meet the Government’s project requirements. These systems include, at a minimum, heating, ventilating, air conditioning and refrigeration (HVAC&R) systems and associated controls, lighting controls, and domestic hot water systems.
R52The Lessor’s TI price proposal must be supported by sufficient cost or pricing data to enable the Government to evaluate the reasonableness of the proposal, or documentation that the Proposal is based upon competitive proposals in accordance with FAR Subpart 15.4obtained from entities not affiliated with the Lessor. Any work shown on the CDs that is required to be included in the Building shell rent or priced as BSAC or for fixtures and/or other TIs already in place must be clearly identified and excluded from the price proposal(s).
R53A minimum of two qualified general contractors (GCs) must be invited by the Lessor to participate in the competitive proposal process. Each participant must compete independently in the process. In the absence of sufficient competition from the GCs, a minimum of two qualified subcontractors from each trade of the Tenant Improvement Cost Summary (TICS) Table (described below) must be invited to participate in the competitive proposal process.
R54Not later than XX days after the acceptance of the Space, the Lessor, at Lessor’s expense, must furnish to the Government a complete set of Computer Aided Design (CAD) files of as-built floor plans showing the Space under Lease, as well as corridors, stairways, and core areas.
R55The Lessor must provide a valid C of O, issued by the local jurisdiction, for the intended use of the Government. If the local jurisdiction does not issue C of O’s or if the C of O is not available, the Lessor may satisfy this condition by providing a report prepared by a licensed fire protection engineer that indicates the Space and Building are compliant with all applicable local codes and ordinances and all fire protection and life safety- related requirements of this Lease.
R56All exterior windows must be equipped with window blinds in new or like new condition, which must be provided as part of the TIs. The blinds may be aluminum or plastic vertical blinds, horizontal blinds with aluminum slats of one- inch width or less, solar fabric roller shades, or an equivalent product pre-approved by the Government.
R57Thermostats must be set to maintain temperatures of 72 degrees F (+/- 3 degrees) during the heating season and 75 degrees F (+/ - 3 degrees) during the cooling season. These temperatures must be maintained throughout the leased Premises and service areas, regardless of outside temperatures, during the hours of operation specified in the Lease. The Lessor must perform any necessary systems start- up required to meet the commercially equivalent temperature levels prior to the first hour of each day’s operation. At all times, the dew point must be maintained below 55 degrees F in occupied spaces, and below 60 degrees F in unoccupied spaces.
R58The Lessor must maintain the Premises and all areas of the Property to which the Government has routine access, including high- touch surfaces (e.g., doorknobs, light switches, handles, handrails, and elevator buttons) in a clean condition and must provide supplies and equipment for the term of the Lease.
R59Lessor must provide snow removal services for the Government on all days for which this Lease has designated normal hours. Lessor must clear parking lots if the accumulation of snow exceeds two inches. Lessor must clear sidewalks, walkways and other entrances before accumulation exceeds 1.5 inches. The snow removal must take place no later than 5:00 AM, without exception.
R60The Lessor must comply with GSA personal identity verification requirements, identified in GSA Order 2181.1 GSA HSPD-12 Personal Identity Verification and Credentialing Handbook.
R61Contractors must submit any contractor-generated documents that contain building information to GSA for review and identification of any CUI building information that may be included. In addition, any documents GSA identifies as containing CUI building information must be marked in accordance with the Order and the Marking Controlled Unclassified Information Handbook... before the original or any copies are disseminated to any other parties.
R62The Lessor must: a. Test for radon any portion of Space planned for occupancy by the Government at or below grade level; b. Report the results to the LCO upon award; and c. Promptly carry out a corrective action program for any radon concentration which equals or exceeds the GSA action levels.
R63Within 48 hours following a water intrusion event, such as a flood, plumbing leak, heavy rain, etc., whereby the Government Space or air zones serving the Space may have become moisture damaged, the Lessor must repair any leakage sources and remediate the moisture damage per the EPA: Mold in Schools and Commercial Buildings (EPA 402-K-01- 001, September 2008) and the current version of ANSI/IICRC: S500 Standard for Professional Water Damage Restoration using a qualified professional.
R64The Lessor agrees to the requirements of Facility Security Level X attached to this Lease.
R65Lessors are encouraged to prioritize products used in the build-out of Space that do not contain Per- and Polyfluoroalkyl Substances (PFAS).

Recent awards in NAICS 531120

The newest federal contract awards in the same industry code from Department of Veterans Affairs, since 1 October 2024. Use them to see who wins this kind of work and at what value.

StartAwardee and buyerAward value
2026-10-01FRONTIER BUILDING SYSTEMS INCDepartment of Veterans Affairs · RENTAL OF OFFICE SPACE TRAILERS BRIDGE$15,000
2026-06-25CITY OF TAMPADepartment of Veterans Affairs · NVGAG TAMPA FL CONVENTION CENTER MAIN VENUE$196,569
2026-04-30ROSE BUD PLAZA LLCDepartment of Veterans Affairs · APPROVED RATIFICATION OF AN UNAUTHORIZED COMMITMENT FOR WAREHOUSE SPACE RENTAL.$26,000
2026-01-03WILLIAMS SCOTSMAN INCDepartment of Veterans Affairs · OFFICE TRAILER RENTAL$124,460
2025-10-01FRONTIER BUILDING SYSTEMS INCDepartment of Veterans Affairs · MODULAR BUILDING RENTAL$30,000
2025-09-01JULIET CONSTRUCTION, LLCDepartment of Veterans Affairs · EMPLOYEE TRAILER RENTAL SERVICES$117,948

Source: USAspending.gov, retrieved 2026-10-25. Award value is the obligated amount reported by the agency.

Automated reading of the documents attached to the notice on SAM.gov when it was posted. Amendments may change them. The official notice always takes precedence.