J066--GRECC Preventive Maintenance Contract, Durham VAMC: requirements and submission rules
32 requirements and 15 submission rules found in the solicitation documents for 36C24627Q0092. Use them as the start of your compliance matrix.
Submission rules that can disqualify a bid
- As a minimum, quotes shall include the— (1) Completed, signed and dated Standard Form (SF) 1449 with the name, address, telephone number of the Quoter, and their Unique Entity Identifier (UEI); Point of Contact and their telephone number and email address; (2) Include all information necessary to evaluate the factors contained in the Basis for Award as described in the solicitation as follows: i.
- Submit the Quote to Monique Cordero at Monique.Cordero@va.gov no later than Friday, January 8, 2027, by 10:30am EST or before the exact time specified in this solicitation.
- All quotes should be submitted via email to Monique.Cordero@va.gov no later than 10:30am EST.
- 36C24627Q0092 Page 50 of 60 (2) If a disclosure is required to be submitted to a contracting office, the offeror shall submit the disclosure as follows: (i) If a Department of Defense contracting office, the offeror shall submit the disclosure to the website at https://dibnet.dod.mil.
- This solicitation quote submission date has been amended to extend the deadline for submission to January 8,2027.
- Technical proposal shall not exceed twenty-five (25) pages in length (minimum 12-point font and no less than ½ inch margins).
- CONTRACT ID CODE FACILITY CODE CODE Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: The above numbered solicitation is amended as set forth in Item 14.
- The Offeror shall review the list of excluded parties in the System for Award Management (SAM) at https://www.sam.gov for entities excluded from receiving federal awards for “covered telecommunications equipment or services.” (2) FASCSA Orders.
- (i) The Offeror shall search in SAM for the phrase “FASCSA order” for any covered article, or any products or services produced or provided by a source, if there is an applicable FASCSA order described in paragraph (e) of FAR 52.240-91, Security Prohibitions and Exclusions.
- (ii) The Offeror shall review the solicitation for any FASCSA orders that are not in SAM but are effective and apply to the solicitation and resultant contract (see FAR 40.204-1(c)(2)).
- (ii) For all other contracting offices, the Offeror shall submit the disclosure to the Contracting Officer.
- The Contractor shall search SAM for the FASC-maintained list of American Security Drone Act—covered foreign entities before proposing, or using in performance of the contract, any unmanned aircraft system.
- (ii) Unless an exception applies according to paragraph (d)(4)(iii) or the Government grants a waiver, contractor shall not export certain sensitive technology to Iran, as determined by the President, and has an active exclusion in SAM (22 U.S.C.
- (2) The Contractor shall search for the phrase “FASCSA order” in the System for Award Management (SAM) at https://www.sam.gov to locate applicable FASCSA orders.
- In accordance with FAR 52.204-7, System for Award Management, prospective quoters must be registered in the System for Award Management (SAM) database under the applicable NAICS Code.
Requirements
| ID | Requirement |
|---|---|
| R1 | OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30 |
| R2 | Quoters shall submit a written Technical proposal that demonstrates the ability to fully perform the requirements as outlined in the performance work statement. The technical proposal must be submitted as a single, combined document, titled “Technical Capability”, in a searchable PDF format with sequentially numbered pages.E.1 |
| R3 | The technical quote shall include information on how the work is to be organized, staffed, and managed.E.1 |
| R4 | Identify all material and supplies used to perform services.E.1 |
| R5 | Provide qualified and certified technicians to accomplish the work.E.1 |
| R6 | Provide an experienced site manager/supervisor to oversee work.E.1 |
| R7 | Establish and implement Quality Inspection plan.E.1 |
| R8 | Management approach to problem resolution.E.1 |
| R9 | Quoters shall submit a narrative describing their specific past performance providing preventative maintenance on Beckman Models (J2-21M Superspeed centrifuge, L8-80 Ultra centrifuge, GPR centrifuge), Eppendorf Models (Refrigerated centrifuge, Refrigerated Microcentrifuge, and Lab-Line Incubator/Shaker Model equipment or similar to the services required in this solicitation. The Past Performance proposal must be submitted as a separate, single document, titled “Past Performance”, in a searchable PDF format with sequentially numbered pages.E.1 |
| R10 | Provide up to three (3) relevant contracts performed withing the last five (5) years that demonstrate your company’s ability to perform these services successfully. For each reference, include the following information: a. Contract number b. Description of specific tasks performed c. Geographic location of contract performance d. Dates of contract performance e. Indicate if the referenced contract was performed by the Quoter or a proposed subcontractor f. State if the Quoter or subcontractor was the prime contractor or a subcontractor g. Name, phone number, and email address of a point of contact who verify contract performanceE.1 |
| R11 | Pricing shall be submitted as requested in section B.2 Price/Cost schedule of this solicitation document.E.1 |
| R12 | For Emergency Services CLINs 0011, 1011, 2011, 3011, and 4011, vendors shall enter an hourly labor rate that includes the cost of parts.E.2 |
| R13 | For Repair Services CLINs 0010, 1010, 2010, 3010, and 4010, vendors shall enter an hourly labor rate that includes the cost of parts. The Government has established an annual Not-to-Exceed (NTE) amount of $3,000.00 for these CLINs. The total amount invoiced under each Repair Services CLIN shall not exceed the annual NTE amount of $3,000.00.E.2 |
| R14 | Responses to provisions that require Quoter completion of information, representations, and certifications (other than those collected via the System for Award Management (SAM)), Quoters are required to have an active Federal Government contracts registration in SAM when they submit a quote and at the time of award;E.1 |
| R15 | Failure to comply with these instructions and provide all requested documents will result in quotes being rejected without further evaluation.E.1 |
| R16 | Contractor shall provide qualified trained and certified personnel who have the experience to perform preventative maintenance on the centrifuges and included instruments to include; inspection of centrifuge and included instruments, calibration of equipment, performing test runs, repairs, and preventative maintenance in accordance with the original equipment manufacturer (OEM) maintenance schedule manuals.B.3 |
| R17 | Contractor shall provide all labor, transportation, personnel, equipment, manuals, tools, materials, parts, and schematics necessary to perform maintenance service for the centrifuges and included instruments.B.3 |
| R18 | Contractor shall provide a preventative maintenance plan outlining all services for each type of equipment and identifying the personnel who will perform the services.B.3 |
| R19 | Contractor shall provide bi-annual preventative maintenance to centrifuges and included instruments in accordance with the original equipment manufacturer (OEM) recommended maintenance manual schedule. Once preventative maintenance services are completed equipment should be calibrated and fully functional.B.3 |
| R20 | Upon completion of bi-annual preventative maintenance, service, repair, or emergency services during regular working hours, the contractor shall obtain the signature of the Contracting Officer’s Technical Representative (COTR) or other designated authorized Durham VAMC GREECC representative acknowledging receipt of services. A copy of the singed service or repair ticket shall be provided to the GRECCC representative.B.3 |
| R21 | The contractor shall give one (1) calendar’s weeks’ notice prior to arriving on-site to perform scheduled bi-annual preventative maintenance. Upon arrival at the station to perform maintenance services or on response to a telephone request for maintenance by an authorized GRECC employee of the Durham VAMC, the contractor shall check in with Engineering Service prior to performing preventative maintenance or emergency services during normal working hours, 8:00am, to 4:30pm, Monday through Friday.B.3 |
| R22 | Contractor shall maintain on-site records of all preventative maintenance conducted and any corrective actions taken.B.3 |
| R23 | Contractor shall respond to telephone calls for emergency repairs within two hours.B.3 |
| R24 | Contractor shall send a trained and certified Field Service Engineer (FSE). The FSE must be on-site within 24 hours of an emergency service call initiated during normal business hours of 8:00am-4:30pm, Monday through Friday, to include weekends and federal holidays.B.3 |
| R25 | For emergency calls outside normal business hours, the contractor shall check in with Operations at the Boiler Plant, building 7, and coordinate with the appropriate Engineering representative.B.3 |
| R26 | The contractor shall submit emergency repair proposals that specially identify all cost and cost components involved for the specific repair, The proposal shall reflect in detail any discounts offered by the contractor.B.3 |
| R27 | Contractor shall wear a uniforms that clearly identify the company and employee in a professional manner to all staff, patients, and visitors of the GRECC.B.3 |
| R28 | all contract employees must present photo identification and provide advanced notice from the requiring service to obtain a VA badge.B.3 |
| R29 | Contractor is required to wear I.D. badge during the entire time he/she is on VAMC grounds. I.D. badges MUST have an identification picture and shall be issued by VAMC.B.4 |
| R30 | All Contractor employees assigned to this contract who create, work with, or otherwise handle records are required to take The Durham VA Medical Center-provided records management training.B.3 |
| R31 | Contractor shall submit all invoices electronically and must contain the obligation number.B.4 |
| R32 | The Contractor shall submit payment requests in electronic form via the VA’s Electronic Invoice Presentment & Payment System at https://www.tungsten-network.com/customer-campaigns/veteransaffairs.B.4 |
Recent awards in NAICS 811210
The newest federal contract awards in the same industry code from Department of Veterans Affairs, since 1 October 2024. Use them to see who wins this kind of work and at what value.
| Start | Awardee and buyer | Award value |
|---|---|---|
| 2027-03-18 | SPECTRUM MEDICAL INCDepartment of Veterans Affairs · QUANTUM HEATER COOLER SERVICE | $22,372 |
| 2027-03-15 | IRIDEX CORPDepartment of Veterans Affairs · IRIDEX LASER MAINT-BASE YEAR-HAMPTON,VA | $11,790 |
| 2027-02-01 | STRYKER SALES, LLCDepartment of Veterans Affairs · ORDERING PERIOD 4 NEPTUNE ROVER AND DOCKING STATION MAINTENANCE FOR IRON MT VAMC | $7,182 |
| 2027-02-01 | STRYKER SALES, LLCDepartment of Veterans Affairs · ORDERING PERIOD 4 NEPTUNE ROVER AND DOCKING STATION MAINTENANCE AT MILWAUKEE VAMC | $74,215 |
| 2027-02-01 | STRYKER SALES, LLCDepartment of Veterans Affairs · ORDERING PERIOD 4 NEPTUNE ROVER AND DOCKING STATION MAINTENANCE FOR DANVILLE VA HOSPITAL | $14,364 |
| 2027-02-01 | STRYKER SALES, LLCDepartment of Veterans Affairs · TASK ORDER 4 NEPTUNE ROVER AND DOCKING STATION MAINTENANCE FOR JBVAMC | $50,275 |
Source: USAspending.gov, retrieved 2026-11-24. Award value is the obligated amount reported by the agency.
Automated reading of the documents attached to the notice on SAM.gov when it was posted. Amendments may change them. The official notice always takes precedence.
Bidding on this? Before you submit, check that every claim in your draft is backed by your records and every requirement above is answered.