NX EQ Transesophageal Echocardiography (TEE) Scanning Systems: requirements and submission rules
43 requirements and 3 submission rules found in the solicitation documents for 36C10X27R0011. Use them as the start of your compliance matrix.
Submission rules that can disqualify a bid
- All interested Offerors must be registered in the System for Award Management (SAM) prior to submitting a proposal.
- Distributors must be authorized distributors/resellers as certified by the OEM (i.e., in OEM letter dated within 12 months of the solicitation close date and duly signed by OEM’s authorized representative) to be eligible for award.
- Contractors are required to submit payment requests in electronic form in accordance with the submission instructions below.
Requirements
| ID | Requirement |
|---|---|
| R1 | Offers shall contain the terms for cost/price and technical capabilities of brand name or equal equipment. |
| R2 | This procurement action is issued as a total service-disabled veteran-owned small business (SDVOSB) set-aside. |
| R3 | Offerors shall provide a proposal for Contract Line-Item Numbers (CLINs) listed in ATTACHMENT A – PRICE COST SCHEDULE - NX EQ TEE SCANNING SYSTEMS. |
| R4 | Offers are due via email by 10:00 AM CT on December 15, 2026, to Contract Specialist, Courtney.Chattman@va.gov, and Contracting Officer, Jessica Smith at Jessica.Smith32@va.gov. |
| R5 | The Contractor must demonstrate the ability to meet all requirements for the solicitation. |
| R6 | This requirement will be solicited and awarded as 'Brand Name or Equal' which requires the quoter indicate that each product being offered as an 'equal' product to the Philips Healthcare EPIQ CVx®. |
| R7 | Offerors will be required to supply a complete TEE Scanning System ready for patient use. This requirement includes complete installation and training for operators, clinicians, and biomedical engineers. |
| R8 | For each equal product, the offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. |
| R9 | The offeror must also clearly identify the item by brand name (if any) and make/model number. |
| R10 | Finally, the offeror must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements. |
| R11 | Equivalent products being proposed in the Technical Volume must also be clearly identified in the Pricing Volume. |
| R12 | Products proposed in the technical volume must be captured on – appear and correspond with -- the Offeror’s pricing volume (Attachment A, Price Cost Schedule of the solicitation). |
| R13 | Offerors may propose any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these ancillary items must be quantified in the Offeror’s pricing volume with an estimated quantity of zero (0). |
| R14 | Only new original equipment is acceptable; no remanufactured or 'gray market' items. No product in development shall be considered. |
| R15 | All items must be covered by the manufacturer's warranty. |
| R16 | The OEM letter must be valid for the life of the contract and demonstrate an uninterrupted source of supply from the manufacturer for the full period of performance. |
| R17 | Those proposals which fail to meet all of the salient characteristics will be rated 'Unacceptable' and will be ineligible for award. |
| R18 | Offerors are required to complete the yellow highlighted area on the SCs Chart below, listing the location where compliance to the SCs can be found. Proposals which do not include the completed Salient Characteristic chart will not be considered for award. |
| R19 | It has been determined that protected health information (PHI) may be used, disclosed, accessed, transmitted, created, stored/maintained, and/or destroyed (providing appropriate proof of destruction in compliance with VA Directive 6371) by the Contractor, and a signed Business Associate Agreement (BAA) will be required. The Contractor will adhere to the requirements set forth within the BAA, referenced in the solicitation, and will comply with all applicable VA/VHA Directives. |
| R20 | The proposed system(s) must feature an OLED live display with a minimum diagonal screen size of 21” |
| R21 | The proposed system(s) must offer real time 3D Transesophageal echocardiography (TEE) capabilities and include applicable TEE probes |
| R22 | The proposed system(s) must utilize tissue harmonic imaging (THI) |
| R23 | The proposed system(s) must be capable of 4D cardiac imaging |
| R24 | The proposed system(s) must contain hard drive image storage capacity of at least 1 TB |
| R25 | The proposed equipment and system(s) must be listed on the published VA 'VistA Imaging Approved DICOM Modality Interfaces' list as an approved DICOM modality |
| R26 | The proposed system(s) must be FDA-approved for diagnostic cardiac procedures to include transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) |
| R27 | The proposed system(s) must feature speckle noise reduction |
| R28 | Payment shall be submitted monthly (within 30 days of delivery) in arrears based upon delivery, acceptance, and receipt of a properly prepared invoice. The Contractor shall submit invoice within 30 days of delivery.B.3 |
| R29 | All invoices from the Contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Request.B.4 |
| R30 | By establishing a contract, the Contractor agrees to supply established item(s) to satisfy the Government’s requirement when an order is placed under the contract during the effective period of performance.B.6 |
| R31 | The contractor agrees to provide complete installation and training for the TEE Scanning systems. Installation services will include delivery, unboxing, hardware setup, software calibration, and system validation to ensure the equipment is fully operational and meets all manufacturer specifications. Following successful installation, the contractor shall provide training for operators, clinicians, and biomedical engineers, covering system operation, patient safety protocols, image acquisition, and routine maintenance/troubleshooting procedures.B.6 |
| R32 | At minimum, the vendor will provide the manufacturer warranty period that may include response time, parts, associated maintenance services, products, and consumables.B.6 |
| R33 | The contractor agrees to ensure that all upgraded improved/replaced products meet Americans with Disabilities Act (ADA) and Health Insurance Portability and Accountability Act (HIPAA) Federal requirements.B.6 |
| R34 | The contractor shall provide the following information for product refresh: (1) A list of specific awarded CLIN(s) being refreshed in the Price/Cost Schedule(to include commercial pricing, discount offered, and price (inclusive of SLA fee)); (2) Product literature for the refreshed product(s). (3) A detailed description of the differences or benefits of refreshed as compared to the CLIN(s) being discontinued or added. (4) Proper identification of any product requirements and/or procedures related to those product(s) proposed to be refreshed or upgraded. (5) FDA approval, if applicable (6) Provide historical sales to VA by product(s), if applicable (7) Copy of Commercial WarrantyB.6 |
| R35 | For any product awarded under this contract removed or recalled by the manufacturer due to defects in the product or potential dangers to patients, or if any required removal or recall is suggested or mandated by a regulatory or official agency, the manufacturer agrees to take the following steps immediately: Notify the COR and CO at the Enterprise Procurement Office, in writing, by the most expeditious manner possible. Provide copies of the notification to the Contracting Officer, Contract Specialist, Contracting Officer’s Representative, and Manager at Product Recall Office, all Agencies and VA Facilities who purchased the product, which include, but not be limited to the following: (1) Complete item description and/or identification, order numbers from customers and the contract number assigned as a result of an issuance on the solicitation; (2) Reasons for modifications, removal or recall; and (3) Necessary instructions for return for credit, replacement or corrective action.B.6 |
| R36 | The Contractor shall accept orders against this contract only from the designated VHA ELCM Ordering Officers when the Delivery Order has been reviewed by the Ordering Officer for this contract.B.6 |
| R37 | The contractor will acknowledge receipt of any order submitted by an individual Ordering Officer specified by appointment against the contract.B.6 |
| R38 | All shipments, either single or multiple container deliveries, shall bear and contain on the delivery tickets or sales slips (external shipping labels and associated manifests or packing lists) the following at a minimum: (i) Name of supplier (ii) Contract/Delivery Order/Task Order number (iii) Date of purchase (iv) Contract number (v) Itemized list of supplies or services furnished (vi) Quantity, unit price, and extension of each item, less applicable discounts (unit prices and extensions need not be shown when incompatible with the use of automated systems, provided the invoice is itemized to show this information). (vii) Date of delivery or shipmentB.6 |
| R39 | The Contractor shall provide an order confirmation within four (4) working days of receipt of the delivery order.B.6 |
| R40 | The Contractor will provide tracking information or use of a website to obtain delivery status and proof of delivery.B.6 |
| R41 | In the case of multiple container deliveries, a statement readable near the VA Order number will indicate total number of containers for the complete shipment (ex. “Package 1 of 2”), clearly readable on manifests and external shipping labels. Packing Slips/Labels and Lists shall include the following: IFCAP PO # ____________ (i.e., 166-E11234) Total number of Containers: Package ___ of ___. (i.e., Package 1 of 3)B.6 |
| R42 | In order for the contracting office to submit the required financial reporting on FPDS-NG the Contractor needs to submit ATTACHMENT E – QUARTERLY SALES REPORT – NX EQ TEE SCANNING SYSTEMS on a monthly basis to the Contract Specialist and COR. The report is due by the 5th of each month.B.6 |
| R43 | The Contractor shall provide a quarterly report, no later than 60 calendar days after the end of each fiscal quarter ending December, March, June, and September. Reports shall be sent electronically to the Government points of contact until the contractor is notified, in writing, of a different point of contact.B.6 |
Recent awards in NAICS 334510
The newest federal contract awards in the same industry code from Department of Veterans Affairs, since 1 October 2024. Use them to see who wins this kind of work and at what value.
| Start | Awardee and buyer | Award value |
|---|---|---|
| 2027-01-15 | TELEFLEX LLCDepartment of Veterans Affairs · MAINTENANCE & SUPPORT | $20,625 |
| 2026-12-15 | PHILIPS NORTH AMERICA LLCDepartment of Veterans Affairs · ORDERING PERIOD 4 | $26,240 |
| 2026-11-18 | NOVOCURE INCDepartment of Veterans Affairs · OPTUNE TRANSDUCER SYSTEM RENTAL - PROSTHETICS | $49,749 |
| 2026-11-12 | NOVOCURE INCDepartment of Veterans Affairs · OPTUNE PLUS TRANSDUCERS 6 MONTH RENTAL | $99,497 |
| 2026-11-09 | NOVOCURE INCDepartment of Veterans Affairs · PROS TRANSDUCERS | $99,497 |
| 2026-11-09 | INSPIRE MEDICAL SYSTEMS, INC.Department of Veterans Affairs · SLEEP APNEA TREATMENT | $25,120 |
Source: USAspending.gov, retrieved 2026-11-14. Award value is the obligated amount reported by the agency.
Automated reading of the documents attached to the notice on SAM.gov when it was posted. Amendments may change them. The official notice always takes precedence.
Bidding on this? Before you submit, check that every claim in your draft is backed by your records and every requirement above is answered.
Amendment issued? Compare it with the original to see every changed requirement, date and limit, free.